01. Start with the contact event
Do you need contact detection, a pressure distribution, surface geometry, shear, or calibrated force? These are different outputs. Ask what is measured directly and what is inferred by a model.
02. Distinguish spatial and force resolution
Pixel or taxel count is not a force accuracy specification. Ask for active area, spatial pitch, force or pressure range, noise, repeatability and the calibration procedure.
03. Check the complete data path
Request raw data examples, units, timestamps, the host interface and the effective frame rate. Include any acquisition board and software required to reproduce the output.
04. Evaluate surface wear and drift
Contact materials, repeated loading, temperature and mounting can affect results. Ask for replacement surface availability, recalibration instructions and documented test conditions.
05. Agree on an evaluation protocol
Define your objects, contact surface, loading range, sample rate and analysis method. Confirm which components and calibration files are included before ordering.
A useful request for quotation
Application / preferred model / required outputs / host system / interfaces / quantity / destination / target delivery date / evaluation criteria.